Search found 8 matches

by angela.marinoni
Fri Nov 04, 2022 10:09 am
Forum: Particle light absorption coefficient and equivalent black carbon concentration, within PM10 fraction
Topic: AE-33 lev0
Replies: 4
Views: 88281

Re: AE-33 lev0

Thanks a lot Thomas for your reply. Actulally, I was wondering if there was a nomenclature inaccuracy: with att1_1, att2_1, are defined as attenuation coefficient in the metadata, but we should report the attenuations. Is it correct? Should the metadata be changed from attenuation coefficien to atte...
by angela.marinoni
Sat Apr 02, 2022 12:17 pm
Forum: Particle light absorption coefficient and equivalent black carbon concentration, within PM10 fraction
Topic: MAAP pressure sensor
Replies: 0
Views: 34065

MAAP pressure sensor

Hello everybody, we are experiencing a recurring error on our MAAP at Monte Cimone. The error code is 0000 0000 0100 8000 (filter change condition already met immediately after filter change and flow deviation >5%). When the error apperars, by checking into the instrument menu, the absolute sensor p...
by angela.marinoni
Fri Nov 19, 2021 9:28 am
Forum: Particle number size distribution – mobility diameter 10 to 800 nm
Topic: TROPOS inversion program
Replies: 4
Views: 67434

Re: TROPOS inversion program

Thanks a lot Kay for your help, we still have some doubts concerning the meaning and differences among the output files created by the Labview program that uses raw and diagnostic files as input and provides as output the following folders: 01_fl1; 01_ra1; 02_flg; 02_ra2; 03_ra3; 09_ein; 10_in0; 11_...
by angela.marinoni
Fri Oct 29, 2021 10:07 am
Forum: Particle light absorption coefficient and equivalent black carbon concentration, within PM10 fraction
Topic: AE-33 lev0
Replies: 4
Views: 88281

AE-33 lev0

Hello everybody, I'm looking at the AE-33 lev0 data template. I see that attenuation coefficients are expected to be reported, even if they are not a direct output of the AE-33 instrument. Do you calculate them with the following formula? Att (λ) = eBC(λ)*sigma(λ)*C (1.57) Is it correct? Maybe it sh...
by angela.marinoni
Fri Oct 29, 2021 8:52 am
Forum: General ACTRIS & GAW recommendation documents
Topic: level 2 flags
Replies: 4
Views: 76234

Re: level 2 flags

Thanks Markus,

we'll procced according your instruction.

Best
by angela.marinoni
Wed Jul 07, 2021 2:35 pm
Forum: General ACTRIS & GAW recommendation documents
Topic: level 2 flags
Replies: 4
Views: 76234

Re: level 2 flags

Thanks Jean-Philippe!

Good idea the formula for local contamination.
Concerning the RH (flag 640), we decided to flag 640 the hourly average only if there are RH flags during at least 50% of the original data.

Cheers
Angela
by angela.marinoni
Thu Jun 17, 2021 1:52 pm
Forum: General ACTRIS & GAW recommendation documents
Topic: level 2 flags
Replies: 4
Views: 76234

level 2 flags

Hello,

when flagging the lev 2 data (horly average), should we report a specific flag that is present in lev 1 data only for a single sample (1 minute)?
Example: relative humidity >40% (flag 640) only during few minutes in the full hour.

Many thanks for your help
Best Regards

Angela
by angela.marinoni
Thu Jun 17, 2021 1:45 pm
Forum: Particle number size distribution – mobility diameter 10 to 800 nm
Topic: TROPOS inversion program
Replies: 4
Views: 67434

TROPOS inversion program

Hello to everybody,

we are currently using the software DMPS_Inversion_V2.16.vi, provided by TROPOS. Can anyone provide the headers of files produced by the mentionad Labview code?

Many thanks for your help
Best Regards
Angela